Standards of Practice
Table of Contents
1. Definitions and Scope.
2. Standards of Practice
2.1. Roof 2.2. Exterior 2.3. Basement, Foundation, Crawlspace &
Structure 2.4. Heating 2.5. Cooling 2.6. Plumbing 2.7.
Electrical 2.8. Fireplace 2.9. Attic & Insulation 2.10. Doors,
Windows & Interior
3. Limitations, Exceptions & Exclusions
4. Glossary of Terms
1. Definitions and Scope
1.1. A Home Inspection is a non-invasive visual examination of a residential
dwelling, performed for a fee, which is designed to identify observed material
defects within specific components of said dwelling. Components may
include any combination of mechanical, structural, electrical, plumbing, or
other essential systems or portions of the home, as identified and agreed to by
the Client and Inspector, prior to the inspection process.
I. A Home Inspection is intended to assist in evaluation of the overall
condition of the dwelling. The inspection is based on observation of the visible
and apparent condition of the structure and its components on the date of the
inspection and not the prediction of future conditions.
II. A home inspection will not reveal every concern that exists or ever could
exist, but only those material defects observed on the day of the inspection.
1.2. A Material Defect is a condition of a residential real property or any
portion of it that would have a significant adverse impact on the value of the
real property or that involves an unreasonable risk to people on the property.
The fact that a structural element, system or subsystem is near, at or beyond
the end of the normal useful life of such a structural element, system or
subsystem is not by itself a material defect.
1.3. An Inspection report shall describe and identify in written format the
inspected systems, structures, and components of the dwelling and shall identify
material defects observed. Inspection reports may contain recommendations
regarding conditions reported or recommendations for correction, monitoring or
further evaluation by professionals, but this is not required.
2. Standards of Practice
2.1. Roof
I. The inspector shall inspect from ground level or eaves:
A. The roof covering. B. The gutters. C. The downspouts. D. The
vents, flashings, skylights, chimney and other roof penetrations. E. The
general structure of the roof from the readily accessible panels, doors or
stairs.
II. The inspector is not required to:
A. Walk on any pitched roof surface. B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes. D. Remove snow,
ice, debris or other conditions that prohibit the observation of the roof
surfaces.
E. Move insulation. F. Inspect antennae, lightning arresters, de-icing
equipment, or similar attachments.
G. Walk on any roof areas that appear, in the opinion of the inspector, to be
unsafe.
H. Walk on any roof areas if it might, in the opinion of the inspector, cause
damage.
I. Perform a water test.
J. Warrant or certify the roof.
2.2. Exterior
I. The inspector shall inspect:
A. The siding, flashing and trim. B. All exterior doors, decks, stoops,
steps, stairs, porches, railings, eaves, soffits and fascias.
C. And report as in need of repair any spacings between intermediate balusters,
spindles, or rails for steps, stairways, balconies, and railings that permit the
passage of an object greater than four inches in diameter.
D. A representative number of windows. E. The vegetation, surface drainage
and retaining walls when these are likely to adversely affect the structure.
F. And describe the exterior wall covering.
II. The inspector is not required to:
A. Inspect or operate screens, storm windows, shutters, awnings, fences,
outbuildings, or exterior accent lighting. B. Inspect items, including
window and door flashings, which are not visible or readily accessible from the
ground. C. Inspect geological, geotechnical, hydrological and/or soil
conditions. D. Inspect recreational facilities. E. Inspect seawalls,
break-walls and docks. F. Inspect erosion control and earth stabilization
measures. G. Inspect for safety type glass. H. Inspect underground
utilities. I. Inspect underground items. J. Inspect wells or springs.
K. Inspect solar systems. L. Inspect swimming pools or spas. M. Inspect
septic systems or cesspools. N. Inspect playground equipment. O. Inspect
sprinkler systems. P. Inspect drain fields or drywells. Q. Determine the
integrity of the thermal window seals or damaged glass.
2.3. Basement, Foundation & Crawlspace
I. The inspector shall inspect:
A. The basement. B. The foundation C. The crawlspace. D. The visible
structural components.
E. And report on the location of under-floor access openings. F. And report
any present conditions or clear indications of active water penetration observed
by the inspector.
G. For wood in contact or near soil.
H. And report any general indications of foundation movement that are observed
by the inspector, such as but not limited to sheetrock cracks, brick cracks,
out-of-square door frames or floor slopes.
I. And report on any cutting, notching and boring of framing members which may
present a structural or safety concern.
II. The inspector is not required to:
A. Enter any crawlspaces that are not readily accessible or where entry could
cause damage or pose a hazard to the inspector. B. Move stored items or
debris. C. Operate sump pumps with inaccessible floats. D. Identify
size, spacing, span, location or determine adequacy of foundation bolting,
bracing, joists, joist spans or support systems. E. Provide any engineering
or architectural service. F. Report on the adequacy of any structural system
or component.
2.4. Heating
I. The inspector shall inspect:
A. The heating systems using normal operating controls and describe the energy
source and heating method. B. And report as in need of repair heating
systems which do not operate. C. And report if the heating systems are
deemed inaccessible
II. The inspector is not required to:
A. Inspect or evaluate interiors of flues or chimneys, fire chambers, heat
exchangers, humidifiers, dehumidifiers, electronic air filters, solar heating
systems or fuel tanks. B. Inspect underground fuel tanks. C. Determine
the uniformity, temperature, flow, balance, distribution, size, capacity, BTU,
or supply adequacy of the heating system. D. Light or ignite pilot flames.
E. Activate heating, heat pump systems, or other heating systems when ambient
temperatures or when other circumstances are not conducive to safe operation or
may damage the equipment. F. Override electronic thermostats. G.
Evaluate fuel quality.
H. Verify thermostat calibration, heat anticipation or automatic setbacks,
timers, programs or clocks.
2.5. Cooling
I. The inspector shall inspect:
A. The central cooling equipment using normal operating controls.
II. The inspector is not required to:
A. Determine the uniformity, temperature, flow, balance, distribution, size,
capacity, BTU, or supply adequacy of the cooling system. B. Inspect window
units, through-wall units, or electronic air filters. C. Operate equipment
or systems if exterior temperature is below 60 degrees Fahrenheit or when other
circumstances are not conducive to safe operation or may damage the equipment.
D. Inspect or determine thermostat calibration, heat anticipation or automatic
setbacks or clocks. E. Examine electrical current, coolant fluids or gases,
or coolant leakage.
2.6. Plumbing
I. The inspector shall:
A. Verify the presence of and identify the location of the main water shutoff
valve. B. Inspect the water heating equipment, including combustion air,
venting, connections, energy sources, seismic bracing, and verify the presence
or absence of temperature-pressure relief valves and/or Watts 210 valves. C.
Flush toilets. D. Run water in sinks, tubs, and showers. E. Inspect the
interior water supply including all fixtures and faucets. F. Inspect the
drain, waste and vent systems, including all fixtures. G. Describe any
visible fuel storage systems. H. Inspect the drainage sump pumps and test
pumps with accessible floats. I. Inspect and describe the water supply,
drain, waste and main fuel shut-off valves, as well as the location of the water
main and main fuel shut-off valves. J. Inspect and determine if the water
supply is public or private. K. Inspect and report as in need of repair
deficiencies in the water supply by viewing the functional flow in two fixtures
operated simultaneously. L. Inspect and report as in need of repair
deficiencies in installation and identification of hot and cold faucets. M.
Inspect and report as in need of repair mechanical drain-stops that are missing
or do not operate if installed in sinks, lavatories and tubs. N. Inspect and
report as in need of repair commodes that have cracks in the ceramic material,
are improperly mounted on the floor, leak, or have tank components which do not
operate.
II. The inspector is not required to:
A. Light or ignite pilot flames. B. Determine the size, temperature, age,
life expectancy or adequacy of the water heater. C. Inspect interiors of
flues or chimneys, water softening or filtering systems, well pumps or tanks,
safety or shut-of valves, floor drains, lawn sprinkler systems or fire sprinkler
systems. D. Determine the exact flow rate, volume, pressure, temperature, or
adequacy of the water supply. E. Determine the water quality or potability
or the reliability of the water supply or source. F. Open sealed plumbing
access panels. G. Inspect clothes washing machines or their connections.
H. Operate any main, branch or fixture valve.
I. Test shower pans, tub and shower surrounds or enclosures for leakage. J.
Evaluate the compliance with local or state conservation or energy standards, or
the proper design or sizing of any water, waste or venting components, fixtures
or piping. K. Determine the effectiveness of anti-siphon, back-flow
prevention or drain-stop devices. L. Determine whether there are sufficient
clean-outs for effective cleaning of drains. M. Evaluate gas, liquid propane
or oil storage tanks. N. Inspect any private sewage waste disposal system or
component of. O. Inspect water treatment systems or water filters. P.
Inspect water storage tanks, pressure pumps or bladder tanks.
Q. Evaluate wait time to obtain hot water at fixtures, or perform testing of any
kind to water heater elements.
R. Evaluate or determine the adequacy of combustion air.
S. Test, operate, open or close safety controls, manual stop valves and/or
temperature or pressure relief valves.
T. Examine ancillary systems or components, such as, but not limited to, those
relating to solar water heating, hot water circulation.
U. Determine the existence or condition of polybutylene plumbing.
2.7. Electrical
I. The inspector shall inspect:
A. The service drop/lateral. B. The meter socket enclosures. C. The
means for disconnecting the service main. D. And determine the rating of the
service amperage. E. Panelboards and overcurrent devices (breakers and
fuses).
F. And report on any unused circuit breaker panel openings that are not filled.
G. The service grounding and bonding. H. A representative number of
switches, receptacles, lighting fixtures, AFCI protected receptacles.
I. And test all Ground Fault Circuit Interrupter (GFCI) receptacles and GFCI
circuit breakers observed and deemed to be GFCI's during the inspection using a
GFCI tester.
J. And report the presence of solid conductor aluminum branch circuit wiring if
readily visible. K. And report on any tested GFCI-tested receptacles in
which power was not present, polarity is incorrect, is not secured to the wall,
the cover is not in place, the ground fault circuit interrupter devices are not
properly installed or do not operate properly, evidence of arcing or excessive
heat is present, or where the receptacle is not grounded or is not secured to
the wall. L. The service entrance
conductors and the condition of the conductor insulation. M. And describe
the amperage rating of the service. N. And report the absence of smoke
detectors. O. Service entrance cables and report as in need of repair
deficiencies in the integrity of the insulation, drip loop, or separation of
conductors at weatherheads and clearances from grade or rooftops.
II. The inspector is not required to:
A. Insert any tool, probe or device into the main panelboard,
sub-panels, distribution panelboards, or electrical fixtures. B. Operate
electrical systems that are shut down. C. Remove panelboard cabinet covers
or dead front covers if they are not readily accessible. D. Operate
overcurrent protection devices. E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of the main service equipment if
not visibly labeled.
G. Inspect the fire or alarm system and components. H. Inspect the ancillary
wiring or remote control devices. I. Activate any electrical systems or
branch circuits which are not energized. J. Operate or reset overload
devices. K. Inspect low voltage systems, electrical de-icing tapes, swimming
pool wiring or any time-controlled devices. L. Verify the service ground.
M. Inspect private or emergency electrical supply sources, including but not
limited to generators, windmills, photovoltaic solar collectors, or battery or
electrical storage facility. N. Inspect spark or lightning arrestors.
O. Inspect or test de-icing equipment. P. Conduct voltage drop calculations.
Q. Determine the accuracy of labeling.
2.8. Fireplace
I. The inspector shall inspect:
A. The fireplace, and open and close the damper door if readily accessible and
operable. B. Hearth extensions and other permanently installed components.
C. And report as in need of repair deficiencies in the lintel, hearth and
material surrounding the fireplace, including clearance from combustible
materials
II. The inspector is not required to:
A. Inspect the flue or vent system. B. Inspect the interior of chimneys or
flues, fire doors or screens, seals or gaskets, or mantels. C. Determine the
need for a chimney sweep. D. Operate gas fireplace inserts. E. Light
pilot flames. F. Determine the appropriateness of any installation. G.
Inspect automatic fuel feed devices. H. Inspect combustion and/or make-up
air devices. I. Inspect heat distribution assists whether gravity controlled
or fan assisted. J. Ignite or extinguish fires. K. Determine draft
characteristics. L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test or dismantle or remove any
component.
N. Perform a National Fire Prevention Association (NFPA) style inspection.
2.9. Attic, Ventilation & Insulation
I. The ventilation inspection shall include:
A. The insulation in unfinished spaces. B. The ventilation of attic spaces.
C. Mechanical ventilation systems. D. And report on the general absence or
lack of insulation.
II. The inspector is not required to:
A. Enter the attic or any unfinished spaces that are not readily accessible or
where entry could cause damage or pose a safety hazard to the inspector in his
or her opinion. B. To move, touch, or disturb insulation. C. To move,
touch or disturb vapor retarders. D. Break or otherwise damage the surface
finish or weather seal on or around access panels and covers. E. Identify
the composition or exact R-value of insulation material. F. Activate
thermostatically operated fans. G. Determine the types of materials used in
insulation or wrapping of pipes, ducts, jackets, boilers, and wiring.
H. Determine the adequacy of ventilation.
2.10. Doors, Windows & Interior
I. The inspector shall:
A. Open and close a representative number of doors and windows. B. Inspect
the walls, ceilings, steps, stairways, and railings.
C. And report as in need of repair any spacing between intermediate balusters,
spindles, or rails for steps, stairways, and railings that permits the passage
of an object greater than four inches in diameter. D. Inspect garage doors
and garage door openers by operating first by remote (if available) and then by
the installed automatic door control. E. And report as in need of repair any
installed electronic sensors that are not operable or not installed at proper
heights above the garage door. F. And report as in need of repair any door
locks or side ropes that have not been removed or disabled when garage door
opener is in use. G. And report as in need of repair any windows that are
obviously fogged or display other evidence of broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window treatments or finish treatments. B.
Inspect central vacuum systems. C. Inspect safety glazing. D. Inspect
security systems or components. E. Evaluate the fastening of countertops,
cabinets, sink tops and fixtures, or firewall compromises. F. Move
furniture, stored items, or any coverings like carpets or rugs in order to
inspect the concealed floor structure. G. Move drop ceiling tiles. H.
Inspect or move any household appliances.. I. Inspect or operate equipment
housed in the garage except as otherwise noted. J. Verify or certify safe
operation of any auto reverse or related safety function of a garage door.
K. Operate or evaluate any security bar release and opening mechanisms, whether
interior or exterior, including their compliance with local, state, or federal
standards. L. Operate any system, appliance or component that requires the
use of special keys, codes, combinations, or devices. M. Operate or evaluate
self-cleaning oven cycles, tilt guards/latches or signal lights. N. Inspect
microwave ovens or test leakage from microwave ovens. O. Operate or examine
any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener,
bread-warmer, blender, instant hot water dispenser, or other small, ancillary
devices. P. Inspect elevators. Q. Inspect remote controls. R.
Inspect appliances. S. Inspect items not permanently installed. T.
Examine or operate any above-ground, movable, freestanding, or otherwise
non-permanently installed pool/spa, recreational equipment or self-contained
equipment. U. Come into contact with any pool or spa water in order to
determine the system structure or components. V. Determine the adequacy of
spa jet water force or bubble effect. W. Determine the structural integrity
or leakage of a pool or spa.
3. Limitations, Exceptions & Exclusions
3.1. Limitations:
I. An inspection is not technically exhaustive. II. An inspection will not
identify concealed or latent defects. III. An inspection will not deal with
aesthetic concerns or what could be deemed matters of taste, cosmetic defects,
etc. IV. An inspection will not determine the suitability of the property
for any use. V. An inspection does not determine the market value of the
property or its marketability.
VI. An inspection does not determine the insurability of the property. VI.
An inspection does not determine the advisability or inadvisability of the
purchase of the inspected property. VIII. An inspection does not determine
the life expectancy of the property or any components or systems therein.
IX. An inspection does not include items not permanently installed. X. These
Standards of Practice apply only to homes with four or fewer dwelling units.
3.2. Exclusions:
I. The inspectors are not required to determine:
A. Property boundary lines or encroachments. B. The condition of any
component or system that is not readily accessible. C. The service life
expectancy of any component or system. D. The size, capacity, BTU,
performance, or efficiency of any component or system. E. The cause or
reason of any condition. F. The cause for the need of repair or replacement
of any system or component. G. Future conditions. H. Compliance with
codes or regulations. I. The presence of evidence of rodents, animals or
insects. J. The presence of mold, mildew or fungus. K. The presence of
air-borne hazards. L. The presence of birds. M. The presence of other
flora or fauna. N. The air quality. O. The existence of asbestos. P.
The existence of environmental hazards. Q. The existence of electro-magnetic
fields. R. The presence of hazardous materials including, but not limited
to, the presence of lead in paint. S. Any hazardous waste conditions. T.
Any manufacturer's recalls or conformance with manufacturer installation or any
information included for consumer protection purposes. U. Operating costs of
systems. V. Replacement or repair cost estimates. W. The acoustical
properties of any systems. X. Estimates of the cost to operating any given
system.
II. The inspectors are not required to operate:
A. Any system that is shut down. B. Any system that does not function
properly. C. Or evaluate low voltage electrical systems such as, but not
limited to: 1. Phone lines. 2. Cable lines. 3. Antennae. 4.
Lights. 5. Remote controls. D. Any system that does not turn on with the
use of normal operating controls. E. Any shut off valves or manual stop
valves. F. Any electrical disconnect or over current protection devices.
G. Any alarm systems. H. Moisture meters, gas detectors or similar
equipment.
III. The inspectors are not required to:
A. Move any personal items or other obstructions, such as, but not limited to:
1. Throw rugs. 2. Furniture. 3. Floor or wall coverings. 4. Ceiling
tiles 5. Window coverings. 6. Equipment. 7. Plants. 8. Ice.
9. Debris. 10. Snow. 11. Water. 12. Dirt. 13. Foliage. 14.
Pets
B. Dismantle, open, or uncover any system or component. C. Enter or access
any area which may, in the opinion of the inspector, be unsafe. D. Enter
crawlspaces or other areas that are unsafe or not readily accessible. E.
Inspect underground items such as, but not limited to, underground storage tanks
or other indications of their presence, whether abandoned or actively used.
F. Do anything which, in the inspector's opinion, is likely to be unsafe or
dangerous to the inspector or others or damage property, such as, but not
limited to, walking on roof surfaces, climbing ladders, entering attic spaces or
negotiating with pets. G. Inspect decorative items. H. Inspect common
elements or areas in multi-unit housing. I. Inspect intercoms, speaker
systems, radio-controlled, security devices or lawn irrigation systems. J.
Offer guarantees or warranties. K. Offer or perform any engineering
services. L. Offer or perform any trade or professional service other than
home inspection. M. Research the history of the property, report on its
potential for alteration, modification, extendibility, or its suitability for a
specific or proposed use for occupancy. N. Determine the age of construction
or installation of any system structure or component of a building, or
differentiate between original construction and subsequent additions,
improvements, renovations or replacements. O. Determine the insurability of
a property.
P. Perform or offer Phase 1 environmental audits.
Q. Inspect on any system or component which is not included in these standards.
4. Glossary of Terms
4.1. Accessible: Can be approached or entered by the inspector safely, without
difficulty, fear or danger.
4.2. Activate: To turn on, supply power, or enable systems, equipment, or
devices to become active by normal operating controls. Examples include turning
on the gas or water supply valves to the fixtures and appliances and activating
electrical breakers or fuses.
4.3. Adversely Affect: To constitute, or potentially constitute, a negative or
destructive impact.
4.4. Alarm System: Warning devices, installed or free-standing, including but
not limited to: carbon monoxide detectors, flue gas and other spillage
detectors, security equipment, ejector pumps and smoke alarms.
4.5. Appliance: A household device operated by use of electricity or gas. Not
included in this definition are components covered under central heating,
central cooling or plumbing.
4.6. Architectural Service: Any practice involving the art and science of
building design for construction of any structure or grouping of structures and
the use of space within and surrounding the structures or the design, design
development, preparation of construction contract documents, and administration
of the construction contract.
4.7. Component: A permanently installed or attached fixture, element or part of
a system.
4.8. Condition: The visible and conspicuous state of being of an object.
4.9. Crawlspace: The area within the confines of the foundation and between the
ground and the underside of the lowest floor structural component.
4.10. Decorative: Ornamental; not required for the operation of essential
systems and components of a home.
4.11. Describe: To report in writing a system or component by its type, or other
observed characteristics, to distinguish it from other components used for the
same purpose.
4.12. Determine: To arrive at an opinion or conclusion pursuant to examination.
4.13. Dismantle: To open, take apart or remove any component, device or piece
that would not typically be opened, taken apart or removed by an ordinary
occupant.
4.14. Engineering Service: Any professional service or creative work requiring
engineering education, training, and experience and the application of special
knowledge of the mathematical, physical and engineering sciences to such
professional service or creative work as consultation, investigation,
evaluation, planning, design and supervision of construction for the purpose of
assuring compliance with the specifications and design, in conjunction with
structures, buildings, machines, equipment, works or processes.
4.15. Enter: To go into an area to observe visible components.
4.16. Evaluate: To assess the systems, structures or components of a dwelling.
4.17. Examine: To visually look. See Inspect.
4.18. Foundation: The base upon which the structure or wall rests; usually
masonry, concrete, or stone, and generally partially underground.
4.19. Function: The action for which an item, component, or system is specially
fitted or used or for which an item, component or system exists; to be in action
or perform a task.
4.20. Functional: Performing, or able to perform, a function.
4.21. Home Inspection: The process by which an inspector visually examines the
readily accessible systems and components of a home and operates those systems
and components utilizing these Standards of Practice as a guideline.
4.22. Household Appliances: Kitchen and laundry appliances, room air
conditioners, and similar appliances.
4.23. Inspect: To visually look at readily accessible systems and components
safely, using normal operating controls and accessing readily accessible panels
and areas in accordance with these Standards of Practice.
4.24. Inspected Property: The readily accessible areas of the buildings, site,
items, components, and systems included in the inspection.
4.25. Inspector: One who performs a real estate inspection.
4.26. Installed: Attached or connected such that the installed item requires
tool for removal.
4.27. Material Defect: A condition of a residential real property or any portion
of it that would have a significant adverse impact on the value of the real
property or that involves an unreasonable risk to people on the property. The
fact that a structural element, system or subsystem is near, at or beyond the
end of the normal useful life of such a structural element, system or subsystem
is not by itself a material defect.
4.28. Normal Operating Controls: Devices such as thermostats that would be
operated by ordinary occupants which require no specialized skill or knowledge.
4.29. Observe: To see through visually directed attention.
4.30. Operate: To cause systems to function or turn on with normal operating
controls.
4.31. Readily Accessible: An item or component is readily accessible if, in the
judgment of the inspector, it is capable of being safely observed without the
removal of obstacles, detachment or disengagement of connecting or securing
devices, or other unsafe or difficult procedures to gain access.
4.32. Recreational Facilities: Spas, saunas, steam baths, swimming pools, tennis
courts, playground equipment, and other exercise, entertainment or athletic
facilities.
4.33. Report: A written communication (possibly including images) of any
material defects seen during the inspection.
4.34. Representative Number: A sufficient number to serve as a typical or
characteristic example of the item(s) inspected.
4.35. Safety Glazing: Tempered glass, laminated glass, or rigid plastic.
4.36. Shut Down: Turned off, unplugged, inactive, not in service, not
operational, etc.
4.37. Structural Component: A component which supports non-variable forces or
weights (dead loads) and variable forces or weights (live loads).
4.38. System: An assembly of various components which function as a whole.
4.39. Technically Exhaustive: A comprehensive and detailed examination beyond
the scope of a real estate home inspection which would involve or include, but
would not be limited to: dismantling, specialized knowledge or training, special
equipment, measurements, calculations, testing, research, analysis or other
means.
4.40. Unsafe: A condition in a system or component which is judged to be a
significant risk of personal injury during normal, day-to-day use. The risk may
be due to damage, deterioration, improper installation or a change in accepted
residential construction standards.
4.41. Verify: To confirm or substantiate.
The aforementioned terms are found within the Standards of Practice.